Lynks Range Datasheet

ModelSM(X.X)kWLLL / SM(X.X)kWPLL
3.66.08.0
Battery Input Parameters
Supported Battery TypeLiFePO4 or Lead-Acid
Battery Input Voltage Range40~60V
Max. Charge Voltage60V (Configurable)
Max. Charge Current60A (Configurable)120A (Configurable)150A (Configurable)
Max. Discharge Current80A (Configurable)130A (Configurable)180A (Configurable)
Battery Capacity (Recommended)100~2000Ah
Charge for LiFePO4 Battery PackCommunicating with BMS of the Battery Pack
PV String Input Parameters
Max. DC Input Power5000W8000W10000W
DC Input Voltage500V
MPPT Voltage Range120~450V
Start-Up Voltage150V
Max. Input Current15A (1 MPPT Channel)15A x 2 = 30A (2 MPPT Channels)23A x 2 = 46A (2 MPPT Channels)
AC Output Parameters (Back-Up)(Feed to Essential Load)
Max. Output Power3600W6000W8000W
Max. Output Apparent Power3600VA6000VA8000VA
Peak Output Apparent Power7200VA12000VA16000VA
Max. Output Current16A26A36A
Nominal Output Voltage220/230/240Vac Single-Phase (Configurable)
Nominal Output Frequency50/60Hz (+/-0.2%) (Configurable)
Max. Bypass Current40A42A
Shift Time (Bypass and Inverter)10ms
Output THDv (Resistor Load)<3%
AC Input Parameter (On-Grid)(Bypass to Essential Load & Charge the Battery/Feed to Home Load)
Max. Input Power (Bypass to Essential Load/Charge the Battery)3600W6000W8000W
Max. Output Power (Feed to Home Load)3600W6000W8000W
Max. Apparent Input Power (Bypass to Essential Load/Charge the Battery)3600VA6000VA8000VA
Max. Apparent Output Power (Feed to Home Load)3600VA6000VA8000VA
Nominal Input/Output Voltage220/230/240Vac Single-Phase (Auto Adjusted to Fit Home Grid)
Nominal Input/Output Frequency50/60Hz (Auto Adjusted to Fit Home Grid)
Max. Bypass Current40A42A
Shift Time (Bypass and Inverter)10ms
Efficiency
Max. Efficiency97.6%
Max. Battery to Load Efficiency94.0%
Europe Efficiency97.6%
MPPT Efficiency99.9%
Protection
IntegratedBattery Over-Charge Protection, Battery Low-Voltage Protection, Over-Temperature Protection, Output Overload Protection, Output Short Circuit Protection, Output Over-Voltage Protection
Compliances
EMC/Safety RegulationIEC 62109-1/2, IEC 61000-6-1/2/3/4, IEC 61727,
IEC 62116, IEC 61683, IEC 60068
General Information
Operating Temperature Range-20ºC ~ +50ºC (>35ºC Derating)
Protection DegreeIP41
Dimension450x403x141mm514x420x140mm570x525x140mm
Weight10.5kg16.1kg24.5kg
Datasheet version V.12 (13/01/26).