Skip to main content

Safety

General Safety Information

  • This device should only be used in accordance with the instructions within this manual and in compliance with local, regional and national laws and regulations. Only allow this device to be installed, operated, maintained or repaired by other person(s) who have also read and understood this manual. Ensure the manual is included with this device should it be passed to a third party.
  • DO NOT allow minors, untrained personnel, or person(s) suffering from a physical or mental impairment that would affect their ability to follow this manual, install, maintain or repair this device.
  • Any untrained personnel who might get near this device while it is in operation MUST be informed that it is dangerous and instructed carefully on how to avoid injury.

Safety Instructions

Danger

HIGH LIFE RISK DUE TO FIRE OR ELECTROCUTION.

The LP IP65 can only be installed by a qualified licensed electrical contractor. This is not a DIY product.

Ensure to follow the safety warnings listed below:

  • Be sure to read this manual thoroughly before installation.
  • Do not attempt to install the inverter by yourself. Installation work must be carried out in compliance with national wiring standards and by suitably qualified personnel only.
  • Do not turn on the power until all installation work is complete.
  • Do not disassemble the inverter. If you need to repair or maintenance, contact a professional service centre.
  • Always use an individual power supply line protected by a circuit breaker and operating on all wires with a distance between contacts of at least 3mm for this unit.
  • The unit must be correctly grounded and the supply line must be equipped with a suitable breaker and RCD to protect people.
  • Disconnect all wires before performing any maintenance or cleaning to reduce the risk of electric shock.
  • The unit is not explosion-proof, so it should not be installed in an explosive atmosphere.
  • Never touch electrical components immediately after the power supply has been turned off since the system can still have residual energy, so electric shock may occur. Therefore, after turning off the power, always wait 5 minutes before touching electrical components.
  • This unit contains no user-serviceable parts. Always consult an authorised contractor for repairs.

Symbols/Safety Signs

SymbolDescription
Risk of danger.
Warning: hot surface.
Risk of electric shock. DO NOT touch the terminal or remove the shell within 5 minutes after disconnecting all power.
Do not disassemble or alter the inverter in any way.
The Inverter is heavy and can cause injury if not handled safely.
ONLY qualified personnel should install or perform maintenance work on the units.
Be careful when touching the inverter! It is an electrical product with risk of electric shock and heating.
Warranty void if seal is broken.
Do not place near open fire or incinerate. Do not use near heaters or hot temperature sources.
Avoid unsuitable shoes for installing and operating the inverter.
Do not step, stand, or climb on this surface.
Do not drop, deform, or impact the inverter.
Do not step or put any objects onto the inverter.
Three-phase.
Protective conductor terminal or earth ground terminal.
Keep out of reach of children, animals, and insects.
Single-phase.
Inverter DC to AC.
Do not submerge the inverter in water or expose it to moisture or liquid.
Net weight in kilograms.
Do not expose the product to sunlight.
Indicates that this product is recyclable.
Max. PV input current.
Direct Current.
Charging.
Discharging.
BATTERY INPUT
Battery Discharge Voltage, Battery Discharge Current, Input Voltage Type, Battery Discharge Power.
PV INPUT
PV Input Voltage, Number of MPPT's, MPPT Input Current & Max PV ISC.
AC OUTPUT
Output Voltage, Input Voltage Type, AC Output Rated Current, Max AC Current, Output Frequency, Max AC ISC, Power Factor & AC Output Rated Power.
CONTINUOUS OUTPUT CURRENT
Maximum Continuous Output Current, Output Frequency and Voltage, & AUX (programmable AC output on battery SOC).
Follow the indicated temperatures.
TEMPERATURE
Ambient, Min & Max.
MANUAL DOWNLOAD
Download the latest version of the instruction manual by scanning the QR code.
WARRANTY REGISTRATION
Scan the QR code to access our website and sign up for the manufacturer’s warranty.
Do not dispose the device, accessories, and packaging with regular waste. Follow local ordinances or contact the manufacturer for disposal guidance.
Refer to the operating instructions.
Contact the supplier within 24 hours if there is anything wrong. In case of leakage contact with eyes or skin, immediately clean with water and seek help from a doctor.
CE mark is attached to the solar inverter to verify that the unit follows the provisions of the European Low Voltage and EMC Directives.
The UKCA marking is used for products placed on the market in Great Britain (England, Scotland and Wales). The UKCA marking applies to most products for which the CE marking could be used.

Product Disposal

DO NOT dispose of this product with domestic waste!

Electrical devices should be disposed of in accordance with regional directives on electronic and / or electronic-waste disposal. In case of further questions, please consult your supplier. In some cases, the supplier can take care of disposal.