When a fault occurs, the corresponding fault code is shown on the display screen. Use the table below to identify the fault and the action to take. If the problem persists after following the recommended steps, contact Sunsynk service.

Fault CodeReasonTroubleshooting Steps
F01Overvoltage fault1. Power off the battery.
2. Contact us.
3. Rest for a while, then restart.
F02Undervoltage fault1. Power off the battery.
2. Contact us.
3. Rest for a while, then restart.
F04Ultimate fault1. Power off the battery.
2. Contact us.
F05Charge overcurrent fault1. Power off the battery.
2. Contact us.
3. Check the external power circuit.
4. Check whether the charging current is excessive.
F06Discharge overcurrent fault1. Power off the battery.
2. Contact us.
3. Check the external power circuit.
4. Check whether the discharging current is excessive.
F07High temperature fault1. Power off the battery.
2. Contact us.
3. Check the ambient temperature and take cooling measures if needed.
4. Restart after the battery pack temperature returns to room temperature.
F08Low temperature fault1. Power off the battery.
2. Contact us.
3. Check the ambient temperature and take insulation measures if needed.
4. Restart after the battery pack temperature returns to room temperature.
F11Cell voltage difference exceeded fault1. Power off the battery.
2. Contact us.
3. Check the voltage sampling wiring for looseness, oxidation or poor contact.
F12Temperature difference exceeded fault1. Power off the battery.
2. Contact us.
3. Restart after the battery pack temperature returns to room temperature.
F13MOSFET high temperature fault1. Power off the battery.
2. Contact us.
3. Restart after the battery pack temperature returns to room temperature.
F14Heating film over-temperature fault1. Power off the battery.
2. Contact us.
3. Restart after the battery pack temperature returns to room temperature.
F19AFE overcurrent fault1. Power off the battery.
2. Contact us.
F24AFE short circuit fault1. Power off the battery.
2. Contact us.
F25AFE communication fault1. Contact us.
2. Power the battery off and on.
F26Cell voltage sampling fault1. Power off the battery.
2. Contact us.
F27Temperature sampling fault1. Power off the battery.
2. Contact us.
F28MOSFET short circuit fault1. Power off the battery.
2. Contact us.
F29EEPROM fault1. Power off the battery.
2. Contact us.
F30Internal communication fault1. Power off the battery.
2. Contact us.
3. Check the IN/OUT wiring is correct.
4. Restart the battery.
F31PCS communication fault1. Contact us.
2. Check the PCS communication cable for looseness or a wrong connection.
F32Host address duplication fault1. Contact us.
2. Power off and restart.
3. Check the host OUT port for looseness and correct wiring.
F45Current limiter board MOSFET adhesion fault1. Power off the battery.
2. Contact us.
F46MOSFET adhesion fault1. Power off the battery.
2. Contact us.
F47Heat adhesion fault1. Power off the battery.
2. Contact us.
F48Heat fault1. Power off the battery.
2. Contact us.
F49Connector overheating fault1. Power off the battery.
2. Contact us.
3. Restart after the battery pack temperature returns to room temperature.
F50Precharge fault1. Power off the battery.
2. Contact us.
F51Charge reverse connection fault1. Power off the battery.
2. Contact us.
F52Terminal post overheating fault1. Power off the battery.
2. Contact us.
3. Restart after the battery pack temperature returns to room temperature.
F53Fuse blown fault1. Contact us.
2. Stop charging and discharging, then power off.
3. Under guidance, open the pack and measure the charge/discharge MOSFET with a multimeter.
F54Voltage disconnection fault1. Power off the battery.
2. Contact us.
F55Temperature disconnection fault1. Power off the battery.
2. Contact us.
F56Inverter emergency stop fault1. Power off the battery.
2. Contact us.